MIK-TDS210-B Conductivity meter

MIK-TDS210-B Conductivity/Hardness/Resistivity Online analyzer, an intelligent Online chemical analyzer, is widely applied for continuous monitoring and measurement of EC value or TDS value or ER value and temperature in the solution in the industry of thermal power, chemical fertilizer, environmental protection, metallurgy, pharmacy, biochemistry, food and water, etc.

Characteristics

Range: 0.01 electrode: 0.02~20.00us/cm

0.1 electrode: 0.2~200.0us/cm

1.0 electrode: 2~2000us/cm

10.0 electrode: 0.02~20ms/cm

Output signal: 4~20mA; Relay; RS485

Power supply: AC220V±10%, 50Hz/60Hz

MIK-TDS210-B Conductivity meterMIK-TDS210-B Conductivity meterMIK-TDS210-B Conductivity meterMIK-TDS210-B Conductivity meterMIK-TDS210-B Conductivity meterMIK-TDS210-B Conductivity meterMIK-TDS210-B Conductivity meterMIK-TDS210-B Conductivity meterMIK-TDS210-B Conductivity meterMIK-TDS210-B Conductivity meterMIK-TDS210-B Conductivity meterMIK-TDS210-B Conductivity meterMIK-TDS210-B Conductivity meterMIK-TDS210-B Conductivity meter

 

  • Advantages

 

Isolating transmitting output, with little interference.

Isolating RS485 communication.

EC/TDS measurement, temperature measurement, top/bottom limit control, transmitting output, RS485 communication.

Configurable manual and auto temperature offset function.

Configurable upper/lower limit warning and delay.

Configurable hummer and LCD backlight switch.

Addition of universal password.

Industrial controlled door keep, to avoid instrument halted.

 

  • Specification

  Product   TDS meter, EC controller
  Model  MIK-TDS210-B
  Measure range  0.01 electrode: 0-20.00us/cm
 0.1 electrode: 0.2~200.0us/cm
 1.0 electrode: 2-2000us/cm
 10.0 electrode: 0.02-20ms/cm
  Basic Error Of Electronic Unit  EC/TES/ER: ±1%FS  NTC10K: ±0.3℃  PT1000: ±0.3℃
  Measuring medium  Liquid
  Temp compensation  NTC10K/PT1000   Manual/ Auto temperature compensation
  Temperature Range  -10-130℃
  Accuracy   2%
  Communication  RS485, Modbus-RTU
  Signal output  4-20mA, maximum loop 750Ω, 0.2%FS
 Relative humidity  (10~85)%RH
 Operation temperature  0~60℃
  Power supply  AC: 220VAC±10%, 50Hz/60Hz  DC: 24VDC±20%
  Relay output  250VAC/3A
 Operation condition  Temperature: 15~65℃  Relative humidity: (5~95)%RH

Need more information?

Contact us for more details about our boilers,solutions and services