MIK-P262-B PTFE Submersible level meter

The anti-corrosion input liquid level transmitter uses a high-performance ceramic pressure sensor as a measuring element to accurately measure the hydrostatic pressure proportional to the liquid level depth, and convert it into a standard current, voltage or RS485 signal output through a signal conditioning circuit , establish a linear correspondence between the output signal and the liquid level depth, and realize the measurement of the liquid depth. The product is made of polytetrafluoroethylene anti-corrosion material, which has excellent corrosion resistance and is widely used in liquid level measurement of acid, alkali and other corrosive media in chemical plants.

Characteristics

Pressure type: Gauge pressure

Measuring range: 0~1m...200m water column

Accuracy: 1%,0.5%(range ≥ 5 meters)

  • The anti-corrosion input liquid level transmitter uses a high-performance ceramic pressure sensor as a measuring element to accurately measure the hydrostatic pressure proportional to the liquid level depth, and convert it into a standard current, voltage or RS485 signal output through a signal conditioning circuit , establish a linear correspondence between the output signal and the liquid level depth, and realize the measurement of the liquid depth. The product is made of polytetrafluoroethylene anti-corrosion material, which has excellent corrosion resistance and is widely used in liquid level measurement of acid, alkali and other corrosive media in chemical plants.

 

  • Parameters
Product  Submersible level meter
Model MIK-P262-B
Pressure type Gauge pressure
Measuring range 0~1m...200m water column
Accuracy 1%,0.5%(range ≥ 5 meters)
Output and power supply range (4~20) mA output (10~32) V
(0~10) V output (12~32) V
RS485 output (8~32) V
Compensation temperature (0~70) ℃
Medium temperature (-40~125) ℃
Storage temperature (-40~85)°C
Overload pressure 200%FS
Long-term stability ±0.5%FS/year
Response time Current, voltage output type pressure ≤ 10ms (up to 90% FS)
RS485 output type pressure ≤ 100ms (up to 90% FS)
Insulation resistance 20MΩ/250VDC
Ingress protection IP68
Load resistance (4~20) mA output: load resistance ≤ (U-10V)/0.02A, U is the supply voltage
Voltage output: load resistance ≥ 5kΩ

 

 

Need more information?

Contact us for more details about our boilers,solutions and services

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.