In the presence of alkaline medium (pH = 11.7) and sodium nitroso ferricyanide, ammonia and ammonium ions in the sample react with salicylate and hypochlorite ions to form a blue compound, and the instrument can calculate the concentration of ammonia in the sample through spectrophotometric conversion.
- Small reagent consumption: The total reagent consumption for a single measurement is less than 3mL, and the maintenance cost is low.
- Separation of toxic waste water and cleaning waste water: Both the amount of toxic waste water and cleaning waste water in a single measurement is less than 15mL.
- Plunger pump quantitative: No contact with reagents, samples, toxic waste water and cleaning waste water, reliable and durable.
- Double optical path detection: Real-time calculation of absorbance, eliminating the interference of the external environment on the optical system.
- Lack of liquid detection and alarm: Automatically identify insufficient sample and reagents supply to avoid no reagent measurement.
- Automatic compensation of turbidity: Automatic compensation based on the turbidity of sample to reduce interference to measurement.
- Automatic range switching: Automatically switch to high-range to measure through dilution if the detection result exceeds the range.
- Key parameter upload: Based on the protocol requirements, key parameters are automatically uploaded to assist in judgment.
- Friendly human-computer interaction: 7-inch color touch screen, the application program is based on the Linux system.
- Support IPv4 network: Compatible with IPv6 network and meet the communication requirements of TCP/IP protocol.
- Support USB and TF card: program upgrade, data export, and data storage can be expanded.
- Technical Parameters
Parameters |
Details |
Measuring range |
(0~2 / 10 / 20 / 50 / 100) mg/L |
Error |
20% Range:±8%; 50% Range:±5%; 80% Range:±3% |
Repeatability |
<10 mg/L:≤2%;≥10 mg/L:≤5% |
24h low concentration drift |
±0.02 mg/L |
24h high concentration drift |
≤1% |
Minimum Maintenance Period |
≥168 h/time |
Digital communication |
RS232、RS485、RJ45 |
Analog communication |
(4~20)mA input; (4~20)mA output |
Power requirements |
(220±22)VAC;(50±1)Hz |
Ambient temperature |
(5~40)℃ |
Size |
300mm×420mm×240mm (W×H×D) |
Weight |
<15 Kg |
- Industrial enterprise waste water automatic monitoring
- Automatic monitoring of waste water in medical units
- Automatic monitoring of water in and out of the sewage treatment plant in the park
- Automatic monitoring of water in and out of urban sewage treatment plants
- Automatic monitoring of inflow and outflow of rural sewage treatment stations
- Automatic monitoring of sewage river and canal water quality
- Automatic monitoring of ship waste water
- Automatic monitoring of waste water in laboratories and automatic monitoring stations
- Watershed and river water quality automatic monitoring
- Automatic monitoring of urban water quality in small watersheds and inland rivers
- Automatic monitoring of water quality in surface drinking water sources
- Automatic monitoring of groundwater quality
- Automatic monitoring of water quality in coastal waters
- Automatic monitoring of drinking water