Product |
Artificial Intelligence PID Regulator |
Model |
MIK-2300 |
Dimension |
A. 160*80*110mm
B. 80*160*110mm
C. 96*96*110mm
D. 96*48*110mm
E. 48*96*110mm
F. 72*72*110mm
H. 48*48*110mm
K. 160*80*110mm
L. 80*160*110mm
M. 96*96*110mm |
Measurement accuracy |
±0.2%FS |
Transmission output |
Analog output----4-20mA、1-5v、
0-10mA、0-5V、0-20mA、0-10V |
Alarm Output |
ALM----With upper and lower limit alarm function, with alarm return difference setting;Relay capacity:
AC125V/0.5A(small)DC24V/0.5A(small)(Resistive load)
AC220V/2A(big)DC24V/2A(big)(Resistive load)
Note: When the load exceeds the relay contact capacity, please do not directly carry the load |
Power supply |
AC/DC100~240V (Frequency 50/60Hz) Power consumption≤5W
DC 12~36V Power consumption≤3W |
Use environment |
Operating temperature(-10~50℃)No condensation, no icing |
Printout |
RS232 printing interface, micro-matched printer can realize manual, timing and alarm printing functions |
Artificial intelligence PID regulator adopts advanced experts PID intelligence algorithm, with high control precision, no overshoot, and fuzzy self-tuning function. The output is designed as modular architecture; you can acquire various control types by replacing different function modules. You can choose PID control output type as any of current, voltage, SSR solid state relay, single / three-phase SCR zero-over triggering and so on. Besides it has another two ways alarm output, and optional transmission output, or standard MODBUS communication interface. The instrument can replace the servo amplifier in driving the valve (valve position control function) directly, external given function, and manual / automatic no-disturbance switch function.
With multiple types of input functions, one instrument can be used with different various input signals, reducing the number of instruments greatly. It has a very good applicability, and can be used with various types of sensors, transmitters used in conjunction to achieve on the temperature, pressure, liquid level, capacity, power and other physical quantities measurements show that, and with all the various actuators on the electrical and electromagnetic heating equipment, electric valves PID regulation and control, alarm control, data acquisition functions.
Input |
Input signals |
Current |
Voltage |
Resistance |
Thermocouple |
Input Impedance |
≤250Ω |
≥500KΩ |
|
|
Maximum input current |
30mA |
|
|
|
Maximum input voltage |
|
<6V |
|
|
Output |
Output signals |
Current |
Voltage |
Relay |
24V Distribution or feeder |
Output load capability |
≤500Ω |
≥250 KΩ (Note: Please replace the module for higher load capacity) |
AC220V/0.6(small) DC24V/0.6A(small) AC220V/3A(big) DC24V/3A(big) According to Remarks |
≤30mA |
Adjustive output |
Control output |
Relay |
Single-phase SCR |
Dual-phase SCR |
Solid relay |
Output load |
AC220V/0.6A(small) DC24V/0.6A(small) AC220V/3A(big) DC24V/3A(big) According to Remarks |
AC600V/0.1A |
AV600V/3A (Should be remarked if driven directly) |
DC 5-24V/30mA |
Comprehensive parameter |
Accuracy |
0.2%FS±1word |
Setting model |
Panel touch key parameter setting values locking; store the setting values permanently |
Display style |
-1999 ~ 9999 measured values, set values, external given values display; 0~100% valve position display 0 ~ 100% output values display; LBD display for working state |
Working environment |
Ambient temperature: 0 ~ 50 ℃; Relative humidity: ≤ 85% RH; Far from strong corrosive gas |
Power supply |
AC 100 ~ 240V(switching power), (50-60HZ); DC 20 ~ 29V |
Power |
≤5W |
Frame |
Standard snap-on |
Communication |
Standard MODBUS communication protocol, RS-485, communication distance up to 1 km, RS-232 ,communication distance up to 15 meters Note: While with communication function, the communication converter should be a active one. |
Note: The output load capacity of external dimensions D, E instrument relay is the AC220V/0.6A, DC24V/0.6A