MIK-RD902T 26GHz Radar level meter

MIK-RD902T Non-contact radar with simple commissioning, trouble-free operation saves time and money. PTFE sensor material, for usage in a wide range of applications - be it in simple storage tanks, in corrosive or aggressive media or high accuracy tank gauging applications.

Characteristics

  • Range: 0~20 m
  • Accuracy: ±3mm 
  • Application:  Liquid
  • Frequency Range: 26GHz

 

  • Introduction

MIK-RD902T Non-contact radar with simple commissioning, trouble-free operation saves time and money. PTFE sensor material, for usage in a wide range of applications - be it in simple storage tanks, in corrosive or aggressive media or high accuracy tank gauging applications.

  • Characteristics

1. Small antenna size, easy to install; non-contact radar, no wear, no pollution.

2.Almost no corrosion, bubble effect; almost not affected by water vapor in the atmosphere, the temperature and pressure changes.

3.Serious dust environment on the high level meter work has little effect.

4.A shorter wavelength, the reflection of solid surface inclination is better.

5.Beam angle is small, the energy is concentrated, can enhance the ability of echo and to avoid interference.

6.The measuring range is smaller, for a measurement will yield good results.

7. High signal noise ratio, the level fluctuation state can obtain a better performance.

8. High frequency measurement of solids and low dielectric constant of the medium.

  • Specification

 Product  Radar level meter
 Model MIK-RD902T
 Measure range 0-20 meters
 Application Liquid
 Process Connection Thread, Flange
 Medium Temperature -40℃~130℃(Standard type), -40℃~230℃(High temp type)
 Process Pressure    -0.1~2.0MPa
 Accuracy ±10mm 
 Protection Grade IP67
 Frequency Range 26GHz
 Signal Output 4-20mA
RS485/Modbus
 Power supply DC(6~24V)/ Four-wire
DC 24V / Two-wire
  • Product Size

 

Radar level transmitter size

  • Installation guide
level meter level meter level meter
Be installed in the diameter of the 1/4 or 1/6.    Note: The minimum distance from the tank  wall should be 200mm. Note:  ① datum  ②The container center or axis of symmetry The top conical tank level, can be installed at  the top of the tank is intermediate, can guarantee  the measurement to the conical bottom  A feed antenna to the vertical alignment surface.    If the surface is rough, stack angle must be used   to adjust the angle of cardan flange of the antenna   to the alignment surface.    (Due to the solid surface tilt will cause the echo attenuation, even Loss of signal.)

 

Need more information?

Contact us for more details about our boilers,solutions and services

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.